ZW7-30kv(40.5kv) Outdoor High Voltage Vacuum Circuit Breaker
This product is suitable for a 30KV(40.5KV), 50HZ three-phase distribution system and can effectively handle load switching currents, overload currents, and short-circuit currents. Additionally, it can serve as the main incoming switch for medium-voltage SVG-enabled power stations, suitable for locations below 2000 meters in altitude, with a spacing of 710mm, and supports custom dimensions to meet installation requirements above 4500 meters.
Compact & Space-Saving Design: Features a mid-set high-voltage vacuum circuit breaker configuration with the operation mechanism box located in the middle, reducing the external longitudinal length by 260mm compared to original models, making it ideal for installations with limited space.
Anti-Condensation & Eco-Friendly Structure: Uses novel filling insulation materials to prevent condensation inside porcelain sleeves and eliminates traditional oil or gas leakage and toxicity concerns.
Integrated Structure & Flexible Installation: Composed of integrated poles, current transformers, a motion mechanism, and a box body. The current transformers can be placed inside or outside the mechanism box for flexible installation.
Smart & Remote Control Capabilities: Can be combined with matching intelligent controllers to perform local switching operations or remote control via communication interfaces (supporting cable, optical fiber, GPRS/CDMA, GSM, etc.) to transmit data back to control centers.
Robust Environmental Adaptability: Designed to operate in surrounding temperatures from -30°C to +60°C, wind pressure up to 700pa (wind speed 34m/s), and III-class air pollution levels, with customizable options for high altitudes exceeding 4500 meters.
| Tech. parameters | unit | data | ||
| Rated voltage | KV | 40.5 | ||
|
Rated insulation level |
1min power frequency withstand voltage | Dry test | KV | 95 |
| (Effective values) | Wet test | KV | 80 | |
| Lightning impulse withstand voltage (peak) | KV | 185 | ||
| Rated current | A | 1250/1600/2000 | ||
| Rated short-circuit breaking current | KA | 20/25/31.5/40 | ||
| Rated sequence of operations | min-0.3s-combine-180s-combine | |||
| Rated capacitor bank breaking current | A | 400 | ||
| Rated breaking times of short-circuit breaking current | Times | 30 | ||
| Rated short-circuit closing current (peak) | KA | 50/63/80/100 | ||
| Rated peak withstand current | KA | 50/63/80 | ||
| Rated short-time withstand current | KA | 20/25/31.5/40 | ||
| Rated short-circuit duration | S | 4 | ||
| Total breaking time | S | ≤0.08 | ||
| Mechanical life | times | 20000 | ||
| Rated operating voltage and rated voltage of auxiliary circuit | V | AC, DC 220, 110 | ||
| Clearance between open contacts | mm | 22±2 | ||
| Contact contact stroke | mm | 4±1 | ||
| Average breaking speed | m/s | 1.7±0.2 | ||
| Average making speed | m/s | 0.7±0.2 | ||
| Contact closing bounce time | ms | ≤3 | ||
| The three phases non-synchronism | ms | ≤2 | ||
| Closing time | ms | ≤150 | ||
| Opening time | ms | ≤60 | ||
| The DC resistance of each phase circuit | (mΩ) | ≤100 | ||
Typical Application Scenarios:
Why Choose Chennuo Electric?
Frequently Asked Questions (FAQ)
Q1: What is the main purpose of the ZW7-40.5kV circuit breaker?
A: It is designed for 40.5kV, 50Hz three-phase power distribution systems to make and break load currents, overload currents, and short-circuit currents, as well as serving as main incoming switches in high-voltage SVG storage substation circuits.
Q2: How does the ZW7-40.5kV prevent condensation and oil/gas leakage?
A: The circuit breaker uses novel filling insulation materials that prevent condensation on the outer sides of the vacuum interrupter and the inner walls of the porcelain sleeve. Furthermore, because it uses a vacuum as the insulation and arc-extinguishing medium, it completely eliminates oil or gas leakage and toxicity issues.
Q3: Can the ZW7-40.5kV operate in high-altitude regions?
A: Yes. For standard units, it is designed for altitudes up to 2000 meters (with a phase spacing of 710mm). However, it can also be custom-manufactured and installed in locations with altitudes of 4500 meters and above with tailored external dimensions.
Q4: What are the environmental and weather condition limits for this circuit breaker?
A: It is rated for surrounding air temperatures between an upper limit of +60°C and a lower limit of -30°C, a wind pressure of no more than 700pa (approx. 34m/s wind speed), no frequent severe vibrations, and a III-class air pollution level.
LW36-30kv(40.5kv) series outdoor sulfur hexafluoride circuit breaker (SF6)
The LW36-35kv(40.5kv)/1250A-2000A high-voltage outdoor SF6 ...
See More
ZW32-12 Series Primary and Secondary Fusion Complete Sets of Column Circuit Breaker (Ordinary Electromagnetic Pillar Type)
The device is an intelligent complete set of equipment ...
See More
ZW32-10kV(12kV) Standard electronic support type outdoor vacuum circuit breaker
ZW32-10kV(12kV) Pole-Mounted Outdoor Vacuum Circuit Breaker ...
See More
ZW32-10kv(12kv) Deeply integrated electronic outdoor vacuum circuit breaker
ZW32-12 Outdoor Vacuum Circuit Breaker combines a vacuum ...
See More
ZW32-12kV Outdoor Pole-Mounted Vacuum Circuit Breaker
ZW32 combines a vacuum circuit breaker, feeder terminal, ...
See More
ZW32-10kV(12kV) Capacitor-Powered Insulation Column Circuit Breaker
This fully integrated circuit breaker combines the circuit ...
See More
ZW7C-40.5kV Series Outdoor High Voltage Vacuum Circuit Breaker (Miniaturized)
The ZW7c-40.5 Series Outdoor High-Voltage AC Vacuum Circuit ...
See More
ZW7B-30kV(40.5kV) Outdoor Vacuum Circuit Breaker
This series of outdoor high-voltage vacuum circuit breakers ...
See MoreProduct Search
Here you can choose products online and find the products you want more quickly and accurately.
Customized Consultation
If you want to customize a product, please contact us, and our team is more than happy to assist you.
Product Procurement
If you want to purchase a product, please contact us and we will provide you with product information and a quotation.
Chennuo Electric Technology Group Co., Ltd
Tel:+86 19303791130
Email:sales@chennuojt.com