Home - Products Center - Vacuum Circuit Breaker/Recloser - Outdoor Vacuum Circuit Breaker - ZW32-40.5kV High Voltage Vacuum Circuit Breaker
Back
ZW32-40.5kV outdoor high-voltage intelligent (permanent magnet) vacuum circuit breaker
ZW32-40.5kV outdoor high-voltage intelligent (permanent magnet) vacuum circuit breaker
ZW32-40.5kV outdoor high-voltage vacuum circuit breaker (Deep integration electronic)
ZW32-40.5kV outdoor high-voltage intelligent (permanent magnet) vacuum circuit breaker
ZW32-40.5kV outdoor high-voltage intelligent (permanent magnet) vacuum circuit breaker
ZW32-40.5kV outdoor high-voltage vacuum circuit breaker (Deep integration electronic)

ZW32-40.5kV High Voltage Vacuum Circuit Breaker

The ZW32-40.5 outdoor high-voltage intelligent (permanent magnet) vacuum circuit breaker consists primarily of an integrated, sealed pole, current transformer, operating mechanism, and enclosure. A disconnector can be added. This circuit breaker features a compact design and a high-quality steel enclosure. The current transformer can be selected based on user needs. This device is primarily used in medium-voltage overhead power lines for opening and closing load currents, overload currents, and short-circuit currents.

Feature
1

The circuit breaker features a three-phase pole structure, consisting of three poles, a mechanism box, and internal transmission components. It utilizes a maintenance-free spring mechanism housed in a fully sealed mechanism box. This ensures the circuit breaker is waterproof and moisture-resistant for outdoor use. It also offers stable and reliable breaking performance without the risk of combustion or explosion. The entire circuit breaker boasts a compact size, light weight, maintenance-free operation, and a long service life.

2

The electronic current transformer (sensor) employed offers numerous advantages, including excellent insulation, compact size, light weight, wide frequency response, no saturation, and excellent electromagnetic interference resistance. Utilizing the LPCT low-power coil principle, low-voltage signals are directly connected to secondary equipment. This technology is widely used for phase and zero-sequence current metering, measurement, and protection signal sampling, reducing errors and simplifying system architecture.

3

The electronic voltage sensor used is a new type of sensor for measuring phase voltage and zero-sequence voltage protection. It employs advanced capacitive voltage division technology to convert high voltage into a low-voltage signal. By calculating this low-voltage signal, phase and zero-sequence voltage data are accurately collected. Because it contains no iron core, it is immune to saturation and offers a wide frequency range, a large measurement range, excellent linearity, and strong anti-interference capabilities. Short-circuiting the secondary voltage output prevents overcurrent and ferromagnetic resonance, eliminating potential major faults in the power system and ensuring the safety and stability of personnel and equipment.

4

The isolating switch and the circuit breaker body can be added to form a circuit breaker + isolating switch combination appliance. The circuit breaker body and the isolating switch have a reliable mechanical interlocking device. Function to prevent misoperation

Parameter
Tech. parameters Unit Value
Rated voltage KV 40.5
Rated current A 630/1250
Rated frequency  Hz 50/60
Power frequency withstand voltage 1min (wet) (dry) between phases, to ground/break
KV 80 95/95
Lightning impulse withstand current (peak) between phases, to ground/break
KV 185
Rated short-circuit breaking current
KA 20/25/31.5
Rated short-circuit making current (peak value)
KA 63/80
Rated peak withstand current
KA 63/80
4s short-time withstand current
KA 25/31.5
Rated operating cycle

Open - 0.1s - Close Open - 6s Close Open - 60s Recover
Rated short-circuit current breaking times
times 30
Mechanical life
times 10000
Mechanism control voltage
V AC/DC220
Secondary circuit 1min power frequency withstand voltage
KV 2
Contact opening distance
mm 18±1
Contact overtravel
mm 4±0.5
Opening speed
m/s 1.4-1.8
Closing speed
m/s 0.4-0.8
Contact closing bounce time
ms ≤5
Phase center distance
mm 560±2
Three-phase opening and closing with different phases
ms ≤2
Closing time
ms ≤100
Opening time
ms ≤50
Weight KG Without isolation 300/with isolation 380


Typical Application Scenarios:

  • Outdoor Power Distribution Networks (40.5kV): Designed for 40.5kV three-phase AC 50Hz outdoor distribution systems.
  • Feeder Automation Systems: Serves as an ideal device to realize distribution line feeder automation, handling fault detection, judgment, and processing.
  • Overload & Short-Circuit Protection: Used to break overload currents and short-circuit currents on overhead lines.


Operating Environment Conditions:

  • Ambient Temperature: Maximum temperature +50℃, minimum temperature -40℃, maximum daily temperature difference 35K.
  • Relative Humidity: Daily average <95%, monthly average <90%.
  • Altitude: Below 2500m.
  • Wind Speed: Not exceeding 35m/s (equivalent to wind pressure 700Pa).
  • Pollution Level: Class IV.
  • Ice Thickness: 10mm.

Key Features & Technical Advantages:
  • All-in-One Integrated Design: Integrates the switch body, power-fetching unit, measurement unit, and control unit into a single system for simple installation and easy maintenance.
  • High-Accuracy Current-Voltage Sensors: Equipped with unified standardized parameters for current-voltage integrated sensors, featuring wide measurement range, high measurement accuracy, and high reliability.
  • Comprehensive Analog Quantities: Provides complete analog quantities to accurately judge and handle various line faults.
  • Feeder Automation Ready: Built specifically to support distribution line feeder automation systems for detection, judgment, and processing.

Why Choose Chennuo Electric?
  • Advanced Secondary Fusion Technology: Combines precise measurement and automated control into a unified pole-mounted unit, reducing external wiring and enhancing grid intelligence.
  • Extreme Weather Resilience: Engineered to withstand harsh outdoor conditions, including low temperatures down to -40℃, heavy ice(10mm), and Class IV heavy pollution levels.
  • Rigorous Quality Standards: Manufactured to provide reliable fault isolation and high-precision monitoring for modern smart power distribution networks.
  • Responsive Technical Support: Backed by professional engineering teams ready to assist with custom parameters, environment evaluations, and global export logistics.

Frequently Asked Questions (FAQ)

Q1: What is a secondary fusion pole-mounted circuit breaker?
A: It is an integrated outdoor distribution device that combines the switch body, power-fetching unit, measurement unit, and control unit to handle current breaking, fault detection, and feeder automation.

Q2: What type of sensors are configured in the ZW32-40.5?
A: It is configured with unified, standardized-parameter current-voltage integrated sensors that feature a wide measurement range, high accuracy, high reliability, and comprehensive analog quantities.

Q3: What are the environmental limits for temperature and altitude?
A: The standard operating temperature ranges from -40℃ to +50℃ with a maximum daily temperature difference of 35K, and it is rated for altitudes below 2500m.

Q4: What should be done if our site conditions exceed the standard environment parameters?
A: If your actual usage environment conditions differ from the specified parameters (such as higher altitude or specific pollution levels), the user and the manufacturer need to negotiate custom solutions.



Install
ZW32-40.5kV outdoor high-voltage vacuum circuit breaker Installation dimension drawing
Related Products
Service
Copyright © 2024 Chennuo Electric Technology Group Co., Ltd Sitexml

Home

Tel

Contact

Top