Home - Products Center - Vacuum Contactor - 400V-2KV - Low Voltage Vacuum Contactor (CKJ20-630/1250A)
Back
Low Voltage Vacuum Contactor (CKJ20-630/1250A)
Low Voltage Vacuum Contactor (CKJ20-630/1250A)

Low Voltage Vacuum Contactor (CKJ20-630/1250A)

This series of vacuum contactors are suitable for AC 50-60HZ, the rated voltage of the main circuit is below 1.6KV, and the rated current is from 160A, 250A, 400A, 630A, 800A, 1000A1250A power network system, for long-distance connection and breaking and frequent start and control of AC motors, transformers and capacitor banks and other occasions have permanent magnet mechanism and electric maintenance two, fully enclosed design, beautiful and generous, cost-effective, and CJ20 installation size interchangeability consistency is good, simple control, more stable and reliable performance, maintenance-free service life is long, cost-effective, is the most ideal replacement product for old-fashioned AC contactors. This series of products also has permanent magnet vacuum contactor, after the product is closed, the mechanical secondary control zero power consumption, more energy-saving power is an excellent energy-saving control switch, which can be used for infrequent action and the occasion that the closing machinery is in a state of maintenance.

Feature
1

Fully enclosed design, beautiful and generous, cost-effective.

2

It is consistent with the CJ20 installation size interchangeability and simple control.

3

The performance is more stable and reliable, maintenance-free, long service life, and cost-effective.

Parameter
The name of the parameter Model 160、250、400/1.14~1.6KV 630、800/1.14~1.6KV 1000、1250/1.14~1.6KV
Rated voltage of the main circuit (V) 1140~1600 1140~160C 1140~1600
Rated current of the main circuit (A) 160、250、400 630、800 1000、1250
Main loop closing capability  (A/100 times) 1600、2500、4000 6300 8000、10000
The main circuit is on/off (A/10) 4000 5000 6000、8000
The ultimate breaking energy is large (A/3) 5000 6300 8000、10000
Electrical life AC3 (10,000 times) 30 30 30
Mechanical life (10,000 times) 100 100 100
Rated operating frequency AC3 (times/h) 300 300 300
Contact opening distance (mm 2±0.2 2±0.2 2±0.2
Overtravel (mm) 1.0±0.2 1.0±0.2 1.0±0.2
Secondary control voltage (V) AC or DC:36/110/220/380or customized